Document Type : Research Paper

Authors

1 Chemical Research and Petrochemical Industries, Ministry of Science and Technology- Iraq

2 Chemical Research and Petrochemical Industries, Ministry of Science and Technology- Iraq.

10.37652/juaps.2009.15350

Abstract

Abstract :Electrochemical corrosion of Ti-20%Co alloy coated with hydroxyapatite (HAP) performance depends on various parameters like applied potential, time, thickness and sintering temperature thus, the optimum parameters required for development of stable HAP coating was found by using electrophortic deposition (EPD) technique. This study discusses the result obtained from XRD and potentiodynamic polarisation, the measured corrosion potential in the synthetic blood plasma for the HAP coated specimens are more noble than the uncoated specimens. The specimen coated for (3) minutes was found to be the best corrosion resistance in comparison with the un coated specimens.

Keywords

Main Subjects

  1. M. kirsch, G Berger, U. Banach, T. Hubet, DDR, June.(1988)."Vitro Ceramics – Anon. Convintional Kind of Ceramics". Inter ceramic, (3).
  2. Brandusa Ghiban,Gabriela Georgetacsmeleata. (2006)."Structural Investigation of electrodeposited Hydroxyapatite on Titanium supports "Rom. Journ. Phys. 51. (2), pp 187–196.
  3. T.M. Sridar, U. Kamachi, Mudali, M. Subbaiyan (2003)."Preparationand terisation of electrophoretically deposited hydroxyapatite coating on type 316 stainless steel" J. Corrosion Science. 45, pp 237-252.
  4. Joon B. Park and Joseph D. Bronzino. (2002)."Biomaterials  principles and applications" PP 47. Boca Raton London New York Washington, D.C,
  5. Zhitomirsky. I. (2000). "Ceramic Films Using Cathodic Electrodeposition"       J Minerals, Metals & Materials Society.52:1 pp 1
  6. Metals Hand book, (1985). Ninth Edition (9)Metalorgraphy and Microstructures ASM. Metals Park ,Ohio 44073 ,
  7. Sella. C, Martin J.C. Lecoeur J.Chanu Le., Harmand M.F, Naji, A and Davidas J.P  (1991). "Biocompatibility and corrosion resistance in biological media of hard ceramic  coatings sputter deposited on metal implants", Mater. Sci and Eng.139,pp49-57
  8. Abdulsalam Khashan Swadi (2008)."Variables Developments of Hydroxyapatite  Coating by Using Electrophortic Deposition Technique" Um-salma Science Journal 5:3 pp423-426
  9. Kannan S.,Balmurugan A and Rajeswari S.(2002)."Development of calcium phosphate coating on type 316L ss and their in vitro response " J. Trends .Biomat.Artif.Organs.16:1pp8-11
  10. Nabeel Alawi Kadhim (2006)."(A Study on Corrosion Behavior of Hydroxyapatite Coated 316LStainless Steel System Used for Surgical Implant Applications)"A thesis submitted for Degree of Master to the Department of Production and Metallurgy Engineering University of Technology Iraq.
  11. M.H.Fathi,Msalehi,A.Sattchi,V.Mortazavi,S.B.Moosavi(2001)"In vitro Behavior of bioceramic Metallic and Bioceramic ,metallic Coated Stainless steel dental implant" Journal of  dental materials. 19, pp 188-198