Document Type : Research Paper

Authors

University of Anbar. College of science

10.37652/juaps.2009.15513

Abstract

A new calcium ion-selective electrode was assembled from complex synthesized by calcium ion and zincon which doped in pvc with suitable mediator and solvent . The prepared complex was identified by UV- Visible and IR spectrophotometry. The new electrode was characterized by its high slope (29.55 ±0.02 mV/decade) compared with calcium phosphate electrode (26.67±0.022 mV/decade) and long lifetime (10 months) . The linear range of the electrode was 10-5-10-1M and the detaction limit was 10-5M . Response time was in the range of 20-60 seconds depending on the concentration of the solution and the lifetime of the electrode. The electrode was linearly working at a pH of (5-10). Most of anions were severely interfered and these were exploited to determine calcium and the anions in precipitation titrations . Cations were slightly interfered especially at high interferent concentrations . The new electrode was applied for the determination of calcium in tap water which offered excellent results compared with flame emission photometric method .

Keywords

1-  Ross, J.W (1967)Scince,156,1378.
2-  Amman, D. , Pretesch, E. and Simon ,J. W (1972),Tetrahedron Lett.,24,2473.
3-  Moody, G. J., and Thomas, J. D. R., (1978),in Ion Selective Electrode in Analytical chemistry, Ld,H.Freiser (Plenum Press, New York) Vol.1 P.287.
4-  Moody, G.J.  and Thomas, J.D.R., (1979) Analyst, 97, 87 in Ion Selective Electrode Methodology,ed,A.K.Covington (CRC Press Boca Raton , Florida) Vol.1 P111.
5-  Craggs, A., Moody, G.J. and Thomas, J.D.R., (1979)  Analyst, 97, 87.
6-  Jaber,A.M.Y.,Moody, G.J.,and Thomas, J.D.R., (1976) Analyst,101,179.
7-  Urban, p., Bachmann, B and Scheldegger, D. (1985) Clin. Chem., , 31 (2) , 264.
8-  Khalil, S.A.H.,Moody,G.J and Thomas, j. D. R., (1986)Anal.Lett,191,1809.
9-  Frant, M.S. , (1994), Analyst,119,2293.
10- Abd-Elmottalib, M., Abu-Alwafa, S.M.and Ahmed, Y.Z. (1985) Egypt. J.Chem, 28, 367.
11- Brader, M.L., (1997), J. Am. Chem. Soc., 119 (32),7603.
12- Vogel’s Textbook of Quantitative Chemical Analysis, Revised by G. H. Jeffery, J. Bassett, J. Merdham and R. C. Denny, (1989), English Language Book Society, Longmans, Inc. ,New york. p752
13- Capitan-Vallvey, L.F. and Fernandez-Ramos, M.D., (2003), Solid-phase Spectrometric assays in., S. Alegret(Ed) Integrated Analytical Systems, Elsevier, Science, B.V., Amstrdam, , p.81.
14- Cano-Raya,C,Fernandez-Ramos, M. D. and Capitan-Vallvey, L. F. (2006) Analytica Chemica Acta, 555, 299.
15- Gaber, M., Mabrrouk, H.E.and Mounir, M., (1991). Thermochemica Acta, , 186, 89.
16- Craggs, A., Moody, G.J. and Thomas, J. D. R. (1974), J.Chem.Educt,51,541.
17- IUPAC (Recommendations for Nomenclature of ISEs ) (1976),Pure Appl.Chem  , 48, 127.
18 Bailey, P.L. , (1980) “Analysis with Ion  Selective Electrodes”(ed.Bouma,J.J.) 2nd edition, Heyden and Son Ltd.,PP.206.211.
19- Palleros, D. R.. ,"Experimental Organic Chemistry,Jonhn Wiley and Sons, Inc,USA (1999), p672.
20- Morf W. E. , Linder. E. and Simon W.  (1975), Anal.Chem.,47,1596
21- Pungor E., (2001) The New theory of Ion-selective Electrodes, Sensors,1,PP.1-12.
22- Craggs, A, Doyle, B., Hassan, S .K. A.G, Moody ,G.J., Thomas, J.D.R. ,(1980), Talanta, , 27, 277.
23- Al.Saa'di B. M. , "Practical Inorganic Chemisitry 1st Edition, Baghdad  Univ. Mosul Press and Publication(1987).p25.