Document Type : Research Paper

Authors

1 university of anbar - college of education for pure sciences

2 Institute of Technical -Anbar

10.37652/juaps.2010.15521

Abstract

Seventy Vertical Electrical Soundings (VES) have been conducted in the study area using Schlumberger configuration with maximum electrode spacing (AB/2) of about 900 m and at the station interval of about 2 km and less. An automatic computerized interpretation method has been used to obtain true resistivity and layer depth from the measured apparent resistivity data at each site. For the geological interpretation, the resistivity values are correlated with the known lithology from available borehole data in the study area. This correlation helps in defining the resistivity ranges for various layers in the area which ranging 22 -165 Ohm-m. The lattest indicate water bearing sand with gravel and form the shallow aquifer in the Bhabhar and Tarai zones. The thickness of this aquifer varies between 2 to 8m in the Bhabhar and 5 to15 m in the Tarai. The depth to the shallow aquifer zone varies from 17 to 32 m in the foothills (Bhabhar zone) and 1 m to 7 m in the Tarai. Due to occurrence of the finer materials in the Tarai belt, the groundwater occurs under confined, semi- confined and unconfined condition.

Keywords

Main Subjects

1- Dwivedi, N. K. and Gupta, P. N. (1961): Behavior of groundwater table in Ganga Yamuna Doab, Uttar Pradesh Irrigation Research Institute, Roorkee. T. M. No. 31, RR (G-42).
2- Pandey, M. P., Raghava Rao, K. V. and Raju, T. S. (1963): Groundwater resources of Tarai-Bhabhar belts and intermountain Doon Valley of Western UTTAR PRADESH. Report Prepared For MFAA. 253p.
3- Anonymous, (1999): Water quality of District Haridwar (U. P.), Tech. Rep. CS (AR) - 10/98-99, National Institute of Hydrology (NIH), Roorkee.
4- Rao, M. S., Kumar, B., Nachiappan R. m. P, Jagmohan. (2000):  Identification of aquifer recharges sources and zones in parts of Ganga- Yamuna Doab using environmental Isotopes. ICIWRM-2000 Proceedings of International Conference on Integrated Water Resources Management for Sustainable Development, 2000, New Delhi India, pp. 271-281.
5- Agrawal, C. S. (1994): Quantitative analysis of aquifer parameters in part of western Utter Pradesh, for groundwater Estimation, Hydrology Journal of IAH.
6- Shakeel, M. (1997): An integrated approach for evaluation of hydraulic properties of alluvial aquifers Ph. D. thesis, Unpublished, Department of Hydrology, Indian Institute of Technology Roorkee, Roorkee.
7- ERADS, (1997): ERADS Imagine, Tour Guides, ERADS, Inc., Atlanta, USA, 454 pp.
8- Zhdanov MS, Keller GV (1994): The geoelectrical methods in geophysical exploration. Elsevier, Amsterdam
9 - Apparao A, Gangadhara Rao T (1974): Depth of investigation in resistivity methods using linear electrodes. Geophys Prospect, Vol. 22 pp.211–223.
10- Schultz R (1985): Interpretation and depth of investigation of gradient measurements in direct current geoelectrics. Geophys Prospect, Vol. 33, pp.1240–1253.
11- Zohdy, A. A. R.  (1989):  New method for automatic interpretation of Schlumberger sounding curve. Geophysics, Vol. 2, pp. 245-253.
12-Israil M, Pachauri (2003): Geophysical characterization of a landslide site in the Himalayan foothill region. Journal of Asian Earth Science, Vol. 22, pp.253–263.